"IIS-RT"-1999. Collection №10
|
Electrochemical activated water: anomal properties, mechanism of biological
effect.
Priluchkiy V.I., Bahir V.M.
THE CONTENT
Introduction
THE CHAPTER 1.
THE FIRST RESEARCHS OF ECA PHENOMENON.
1.1. How "alive" and "dead" water was discovered.
1.2. Development of new means of ECA.
1.3. Factors of physicochemical activity of ECA - mediums.
1.4. Medicobiological backgrounds of electrochemical regulation.
1.5. Indirect electrochemical handling of blood serum of large horned
cattle in dialyzer " a simulated kidney ". (a stand experiments).
1.6. Probable gamut of detrusions (redox potential) ROP of interior
mediums of organism at drink of catholyte.
1.7. Redox area of dwelling medium of microorganisms.
THE CHAPTER 2.
REDOX POTENTIAL AS EXPONENT OF "ELECTRONIC EQUILIBRIUM" OF
CHEMICAL AND BIOLOGICAL SUBSTRATUMS.
2.1. Explanation of concept "redox potential ".
2.2. ROP as an exponent of electronic equilibrium of fluid biological
mediums of organism.
2.3. Redox potential of interior medium of organism: Physiological and
pathophysiological sense, problem of measuring and regulation.
2.4. Redox potential as a measure of electronic pressure.
THE CHAPTER 3.
ABNORMAL PROPERTIES OF ECA - WATER MEDIUMS AND PERSPECTIVES OF ELECTROCHEMICAL
REGULATION OF INTERIOR. MEDIUMS ORGANISM EXPONENTS.
3.1. Controversy concerning a phenomenon " electrochemical activation
".
3.2. Allocation of conjugate values рН and ROP of water mediums subjected
to electrochemical handling as contrasted to by similar allocation these
exponents in water mediums which are not exposed to electrochemical
action.
3.3. Dynamic of exponents рН and ROP of catholyte on water base with
a different mineralization level during its storage.
3.4. Definition of terms "water" and "solution"
with reference to technology of ECA.
3.5. Ability of ECA - SOLUTIONS "to remember" a status of
electroactivation at imposed changes or at bracing рН in buffer intermixtures.
3.6. Indirect biochemical corollary of reception of catholyte inside.
(Exponents рН and ROP in urine after drink of single portion of drinking
water catholyte).
3.7. Theoretical comparison guessed electron-donor of catholyte action
on interior medium of organism with activity antioxidizing of preparations
and radioprotectors.
3.8. Appearance of supersummation ofelectron-donor properties of ECA
- WATER and substances with antioxidizing activity.
3.9. Opportunity of deriving ECA - mediums on base of distilled water.
3.10. Ability of saline solutions prepared on ECA - WATER to maintain
electron-nonequilibrium properties of initial solvent.
3.11. Noncontact ECA - direct proof of water activation which is not
depending from occurrences in it of yields of electrochemical synthesis.
3.12. Particularities рН-measurement in ECA - SOLUTIONS.
3.13. General principles of technology of ECA - SOLUTIONS synthesis
in electrochemical device on base of module FEM.
THE CHAPTER 4.
MODEL PERFORMANCE OF SYSTEMIC ACTIVITY OF ECA - SOLUTIONS ON INTERIOR
MEDIUM OF ORGANISM.
4.1. Possible limits of change ROP in organs and tissues.
4.2. Compatibility of ECA - SOLUTIONS with life of cell-like test-objects.
4.3. Complex description of physiological homeostasis systems as objects
of electrochemical regulation with correct for possible points of the
application of activity ECA - SOLUTIONS.
4.4. Possible pathophysiological corollaries of activity of ECA - SOLUTIONS
on biochemical and cell-like level.
4.5. Sano-genetic model of activity of ECA - SOLUTIONS in interior medium
of organism.
4.6. Probable mechanisms of ECA - SOLUTIONS activity at a cell-like
level.
4.7. Oxidizing, aging, physiological stress.
4.8. Model experiment on study of ECA - SOLUTIONS influence on a tissue
array.
4.9. Infringement of peroxide homeostasis of fluid biological mediums
at some views of pathology and at experimental actions.
4.10. Social - ecological aspect of management of the electronic status
of interior medium of organism.
THE CHAPTER 5.
EXPERIMENTAL STUDY OF BIOLOGICAL PROPERTIES "ALIVE" AND "DEAD"
WATER. APPLICATION OF ECA - SOLUTIONS FOR ZOOTECHNICAL PURPOSES.
5.1. Activity of ECA - SOLUTIONS on organism of small laboratory animal
on datas of the Tashkent branch АМS USSR.
5.2. Indirect evaluation ROP of blood of the man, regulation ROP of
blood at haemodialysis.
5.3. Mobility of cell-like test-object in dialysis solution on base
of cathode -actuated demineralizated water.
5.4. Activity of ECA - SOLUTIONS on morphology and viability of bacteria.
5.5. Disinfecting property of actuated anolyte.
5.6. Toxicological evaluation of ECA - SOLUTIONS synthesized by device
STEL.
5.7. Influence of catholyte to mechanisms of immunitny-genesis.
5.8. Radioprotector and radiation-sensitizing properties of ECA - SOLUTIONS.
5.9. Influence of catholyte and anolyte on activity of wheat leaves
catalase, brought up from seeds, wetted by ECA - SOLUTIONS.
5.10. Activity of ECA - SOLUTIONS on kinetics of proteolysis in vitro.
5.11. Giving to drink by cathode-actuated water of broiler chickens
and meat hens.
5.12. Application of devices СТЭЛ in Latvia.
THE CHAPTER 6.
APPLICATION ECA IN MEDICINE, TECHNICAL, ALIMENTARY, BIOTECHNICAL AND
AGRICULTURAL TECHNOLOGIES.
6.1. Washing, regeneration, improving of biocompatibility and functional
properties of products of medical assigning.
6.2. ECA in alimentary and biological industry.
6.3. ECA - SOLUTIONS in a cosmetology.
6.4. Technological using of ECA - SOLUTIONS in an agriculture and at
handling of agricultural raw material.
6.5. Conditioning of swimming pools water and drinking radiants of doubtful
quality.
THE CHAPTER 7.
ELECTROCHEMICAL MANAGEMENT OF DRINKING WATER PROPERTIES.
7.1. Common principles of drinking water clearing. The physicochemical
backgrounds of electrochemical handling of low mineralization water.
7.2. Electrochemical devices "Emerald" on base of module FEM
for disinfection and clearing of drinking water.
7.3. Operating features of devices "Emerald". Exponents of
quality of electrochemical -stripped drinking water.
7.4. Efficiency of devices "Emerald" on exponents of water
clearing from heavy metals combinations from positions of the concept
accepted in Great Britain and USA.
7.5. Comparative evaluations of efficiency of water clearing by device
"Emerald" and domestic devices of filtration -getter type.
7.6. Biological activity of water clearing by devices "Emerald".
THE CHAPTER 8.
MEDICAL ACTIVITY OF ECA - SOLUTIONS.
8.1. Justification of ECA - SOLUTIONS dose intended for reception inside
with therapeutic purposes.
8.2. Experience of medical application of ECA - SOLUTIONS.
8.3. Experimental research of medical application of neutral anolyte,
synthesized by devices STEL.
8.4. Comparative analysis of different directions of medical application
of ECA - SOLUTIONS.
8.5. Bath together with a catholyte.
8.6. Application of ECA in extreme medicine.
Conclusion.
|